1.
Journal of Shanghai Jiaotong University(Medical Science) ; (6): 845-849, 2009.
Article in Chinese | WPRIM | ID: wpr-634087

ABSTRACT

Objective To reconstruct a computational fluid dynamics (CFD) model of human nasal cavity, and make comparison analysis with acoustic rhinometry and rhinomanometry. Methods One healthy volunteer was performed CT scanning of nasal cavity, three dimensional CFD model was established by Simplant 10.0 and Gambit 2.3.16, and Fluent 6.3.2 was employed to simulate the airflow of nasal cavity. Acoustic rhinometer was used to assess the area of nasal cavity, rhinomanometry was adopted to measure the airflow and intranasal pressure drop during inspiration, and the results were compared with those obtained from CFD model. Results Cross section area of nasal cavity obtained from CFD model matches well with that measured by acoustic rhinometer within 30 mm distance from nostril, while the latter was larger than the former beyond 50 mm distance from nostril. The trend of intranasal pressure drop at different airflows measured by CFD model was the same as that measured by rhinomanometry, while the transnasal pressure obtained by CFD model was lower than that recorded by rhinomanometry. Conclusion CFD model can accurately simulate the shape of nasal cavity and measure the parameters of intranasal airflow, which helps to understand the airflow characteristics of nasal cavity.